BTGCF - YELLOW ST CA WATERBORNE, 2343A9

  • MSDS: BTGCF
  • Manufacturer: MORTON INTERNATIONAL
  • Product Name: YELLOW ST CA WATERBORNE, 2343A9
  • National Stock Number: 8010-00N043433
Product Identification

Product ID:YELLOW ST CA WATERBORNE, 2343A9
MSDS Date:03/22/1992
FSC:8010
NIIN:00N043433
MSDS Number: BTGCF

Responsible Party
MORTON INTERNATIONAL
1021 N. MISSION RD
LOS ANGELES, CA 90033
US

Emergency Phone: 213-225-4154;800-424-9300(CHEMTREC)

Info Phone: 213-225-4154

Cage: 7D283

Contractor
MORTON INTERNATIONAL
LOS ANGELES, CA 90033 US

Telephone: 213-225-4154

Cage: 7D283

Ingredients

LEAD SULFOCHROME; (LEAD SULFOCHROMATE)

CAS: 1344-37-2

OSHA PEL 0.05 MG/M3

ACGIH TLV: 0.05 MG/M3


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

OSHA PEL 0.05 MG/M3 RDUST

ACGIH TLV: 0.05 MG/M3 RDUST


CALCIUM CARBONATE

CAS: 1317-65-3

RTECS: EV9580000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


ETHYL ALCOHOL

CAS: 64-17-5

RTECS: KQ6300000

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


METHANOL

CAS: 67-56-1

RTECS: PC1400000

OSHA PEL 200PPM;250PPM STEL,S

ACGIH TLV: 200PPM;250PPM STEL,S

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


1.69 LB/GAL

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


PG 341, 1987; NTP 6TH ANNUAL REPORT ON

RTECS: 9999999ZZ


COMPOUNDS APPEAR ON NAVY LIST OF OCCUP

RTECS: 9999999ZZ


HLTH PROFESSIONALS CONCERNING LATEST HAZ LIST INFO &

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST: GI DISTRESS. SKIN:
REPEATED OR PROLONGED LIQUID CONT MAY CAUSE IRRIT W/DISCOMFORT &
DERM, MAY ALSO CAUSE ALLERGIC SKIN RXN. INHAL: MAY CAUSE NOSE &
THROAT IRRIT. MAY CAUSE NERV SYS DEPR ESS CHARACT BY FOLLOWING
PROGRESSIVE STEPS: HDCH, DIZZ, NAUS, STAGGER GAIT, CONFUSN, UNCON.
REPORTS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CHROMIUM COMPOUNDS: IARC GROUP 1, SUPP
7, P 165, 1987; SILICA, CRYSTALLINE-CRISTABOLITE, IARC GROUP 2A,
SUPP 7, (ING 7)
Effects of Overexposure:HLTH HAZ: HAVE ASSOC RPTD & PRLNGD OVEREXP TO
SOLV W/PERM BRAIN & NERV SYS DAM. CHRONIC: CHEM AS NOTED IN LEAD
STD, RPTD & PRLNGD EXPOS MAY CAUSE DELAYED EFTS INVOLVING BLOOD,
GI, NERV, & REPROD SYS. ING 2: MAY CAUSE IRRIT TO MUC MEMB.
RPTD/PRLNGD EXPOS/ OVERWHELMING INHAL OF DUST MAY AFFECT LUNGS.
NOTE LEAD (ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: CALL A PHYS IMMED & HAVE NAME OF INGRED AVAIL. SKIN:
IMMED FLUSH W/PLENTY OF SOAP & WATER FOR @ LST 15 MIN WHILE
REMOVING CONTAMD CLTHG & SHOES. EYE: IMMED FLUSH W/PLENTY OF WATER
FOR @ LST 15 MIN, CALL A PHYS. IF IRRIT OCCURS, CONT A PHYS.
INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG GIVE ARTF RESP, PREF MOUTH
TO MOUTH. IF BRTHG DFCLTY PERSISTS/OCCURS LATER, CONSULT A PHYS.

Fire Fighting

Extinguishing Media:USE CHEMICAL FOAM, DRY CHEMICAL, OR CARBON DIOXIDE.
ALCOHOL FOAM FOR POLAR SOLVENTS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL
CLSD CONTRS TO PVNT PRESS BUILDUP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FLASHPOINT, EMITS FLAMM
VAPS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLOS. FINE MISTS/SPRAYS
MAY BE FLAMM @ TEMPS BELOW FLASH POINT.

Accidental Release

Spill Release Procedures:STOP DISCHARGE, IF IT CAN BE PERFORMED SAFELY,
& CNTN MATL. IF SUBSTANTIAL QTY IS SPILLED, RECOVER W/PUMP/VACUUM
TRUCK. EXPLO PROOF EQUIP SHOULD BE USED IF PROD IS FLAMM/COMBUST,
OTHERWISE, USE A SYNT HETIC ABSORB. PLACE CONTAMD MATL IN A (SUPP
DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTD AREA.
DO NOT CUT, GRIND, WELD/DRILL NEAR THIS CONTR.
Other Precautions:CONTR CAN BE HAZS WHEN EMPTY, BECAUSE IT CAN RETAIN
PROD RESIDUE. THEREFORE, DO NOT REUSE CONTR FOR FOOD, CLTHG/PROD
FOR HUMAN OR ANIMAL CONSUMPTION OR WHERE SKIN CONT MAY OCCUR.
ALWAYS OBEY HAZ WARNI NGS & HNDLE CONTRS AS IF THEY WERE FULL.

Exposure Controls

Respiratory Protection:WHEN ESTABLISHED AIRBORNE EXPOS LIM ARE
SURPASSED, WEAR NIOSH/MSHA APPROVED EQUIP, DETERM APPROP TYPE EQUIP
FOR SPEC APPLICATION BY CONSULTING RESPIRATOR MFR. OBSERVE RESP USE
LIMITATIONS SPECIFIED BY NIOSH/MSHA OR MFR.
Ventilation:LOCAL EXHAUST TO MAINTAIN VAPOR CONC BELOW THRESHOLD LIMIT
VALUE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM SAFETY GOGGLES
Other Protective Equipment:EYE BATH RECOMMENDED.
Work Hygienic Practices:REMOVE & WASH CONTAMD CLTHG BEFORE REUSE.
DISCARD SHOES IF SATURATED.
Supplemental Safety and Health
SPILL PROC:SUITABLE CONTR FOR DISP. APPROP SFTY MEASURES & PROT EQUIP
SHOULD BE USED. DO NOT FLUSH TO SEWER, STREAM/ OTHER BODIES OF
WATER. COMPLY W/ALL APPLIC GOVT REGS ON SPILL REPORTING. WASTE DISP
: AN AUTHORIZIED FACILITY/TREAT @ AN ACCEPTABLE WASTE TRTMT
FACILITY. SEE OSHA STD 29 CFR 1910.1025 FOR HNDLG LEAD CMPDS

Chemical Properties

HCC:N1
Vapor Density:HVR/AIR
Spec Gravity:1.56
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:40.73

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, HYDROFLUORIC ACID.
Stability Condition to Avoid:HEAT, SPARKS, AND OPEN FLAME.
Hazardous Decomposition Products:MAY LIBERATE CARBON MONOXIDE, CARBON
DIOXIDE, AND UNIDENTIFIED ORGANIC COMPOUNDS IN BLACK STONE.

Disposal

Waste Disposal Methods:DISPOSE OF WASTE I/A/W LOC, ST & FED REGS. OF
METH OF DISP, CURRENTLY AVAIL, IT IS RECOM THAT AN ALTERNATIVE BE
SELECTED ACCDG TO THE FOLLOWING ORDER OF PREFERENCE BASED UPON
ENVIRON ACCEPTABILITY; RE CYCLE/REWORK IF @ ALL FEASIBLE, INCIN
@(SUPP DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.